The tariff design

The total cost of energy consumed by the customer is the summation of the following factors:

Total Cost= Bulk Supply Charge + Transmission Charge + Distribution System Charge + Supply Charges

These different charges correspond to the different stages of electricity delivery to the customer as shown in the diagram below:

1495863788_tarifdesign.jpg

TOD Register Identification T1 T2 T3 T4
Register Off-Peak Weekday-Peak Night-Peak Friday-Peak
Time Slot 02:00 to 13:00
17:00 to 22:00
16 Hrs
13:00 to 17:00
4 Hrs
22:00 to 02:00
4 Hrs
13:00 to 17:00
4 Hrs
  Week day Week day Week dayk Friday
 
  Off -Peak Night-Peak weekday Day-Peak weekend Day-Peak
January - March 12 12 12 12
April 14 14 14 14
May - July 17 27 67 39
August - Septembet 15 21 26 19
October 14 14 14 14
November - December 12 12 12 12
 

Note: All prices are in Baize per Kwh and the above rates might be changed in yearly basis. The above table represents 2016 rates.

1495863823_c-bill.jpg